Starting a single loading (if the weighing indicator is enabled for the loading operation of the single component)

In order to start the loading of a single component, it is necessary to carry out the following operations:

  • Enter the total weight menu, then press the key ptm-f1  corresponding to the key centralina__0009_gsa
  • Select the wished component, by using the keys     centralina__0019_gsaand    centralina__0018_gsa, and confirm the choice by pressing the key centralina__0022_gsa
  • Enter the quantity to load by means of the numeric keyboard, and confirm by pressing the key centralina__0022_gsa
  • Confirm the start of the loading by pressing the key centralina__0022_gsa

 

We remind the user that the loading of the recipe does NOT start, should one of the following conditions occur:

  • There is a zeroing error upon starting the loading, as the material in the tank exceeds the maximum zeroing threshold.
  • The remaining quantity in the tank exceeds the maximum remaining threshold set out in the codes.
  • The sum between the quantity to load and the remaining quantity in the tank at the beginning of the loading exceeds “Tank Error” threshold.

The quantity to load of the recipe exceeds the value of “Tank Error”.

 

 

 