GSA
Product detail
GSA
WEIGHING COMPUTER WORKING MODE
CONNECTION OF THE SYSTEM
KEYBOARD AND DISPLAY
TO START
- Switch-on / Switch-off
- Display upon switch-on
- Tare resetting
- Partial load with weight zeroing
- Displaying the weight value measured by the external scales
- Starting an automatic loading
- Starting a single loading
- Start of a recipe by input
- Check of the starting time of a time programming
- Download of loading data on USB Pendrive
- Control of the additional Multilink modules in error
- Block of modifications by means of PIN CODE
Starting a single loading (if the weighing indicator is enabled for the loading operation of the single component)
In order to start the loading of a single component, it is necessary to carry out the following operations:
- Enter the total weight menu, then press the key corresponding to the key
- Select the wished component, by using the keys and , and confirm the choice by pressing the key
- Enter the quantity to load by means of the numeric keyboard, and confirm by pressing the key
- Confirm the start of the loading by pressing the key
We remind the user that the loading of the recipe does NOT start, should one of the following conditions occur:
- There is a zeroing error upon starting the loading, as the material in the tank exceeds the maximum zeroing threshold.
- The remaining quantity in the tank exceeds the maximum remaining threshold set out in the codes.
- The sum between the quantity to load and the remaining quantity in the tank at the beginning of the loading exceeds “Tank Error” threshold.
The quantity to load of the recipe exceeds the value of “Tank Error”.